- Petrol / CNG / LPG selection
- 7 Segment LED display
- Non dispersive Infrared (NDIR) technology
- Automatic condensate discharge
- Automatic zero calibration
- Digital span calibration
- Easy update of software in the field through USB port
- DC operation facility available for “mobile road tests” using vehicle battery
- Display of Lambda / AFR / PEF
- Separate Indication for battery Low / High voltage
- Electronic leak check facility
- Gas scrubber for cleaning of impure particles
- USB interface for PC
- Conforms to ISO 3930
- NOx measurement (Optional)
- Features
- Technical Specification
- Standard Accessories
- Optional Accessories
-     Videos    
-   Downloads  
Measurement parameters | Range | Resolution |
---|---|---|
CO (Carban Monoxide) | 0 - 15% | 0.01% |
CO2 (Carbon Dioxide) | 0 - 19.9% | 0.01% |
HC(Hydro Carbon) | 0 - 20000 PPM | 1 PPM |
O2 (Oxygen) | 0 - 25% | 0.01% |
NOx (Oxides of Nitrogen) | 0 - 5000 PPM | 1 PPM |
AFR | 0 - 30% | 0.01% |
Lambda | 0.20 to 2.00 | 0.001 |
Engine RPM (Battery based) | 400 to 9990 RPM | 10 RPM |
Engine Oil temperature | 0 - 150°C | 1°C |
Operating temperature | +5°C to +45°C | |
Measuring gas intake | 3 Litres/minute | |
Response time | < 15 Sec.(for Sample probe length of 3m) | |
Warm-up time @25°C & above | < 3 minute | |
Power Supply | 12V DC ±2V battery 100-265V AC, Single phase, 50-60Hz | |
Power | 25W |